0.65mpa 3D KN95 Non Woven Mask Making Machine

Wuxi Sunye Precision Machinery Co.Ltd

0.65mpa 3D KN95 Non Woven Mask Making Machine

Brand Name : Sunye

Model Number : ZPFM95

Certification : CE

Place of Origin : China

MOQ : 1

Price : 110000-120000$

Payment Terms : T/T, L/C

Delivery Time : 10-15 working days

Packaging Details : Wooden box

Product Name : Face Mask Making Machine

Air source : 0.45mpa-0.65mpa

Air supply : 0.6Mpa-0.8Mpa

Power supply voltage : 380V ± 10% 50Hz

Installation site : indoor flat ground

Altitude : < 2000m

Ambient temperature : 5 ℃ ~ 35 ℃

Size : (9M*1.4M*2M)(L*B*H)

Production Capacity : 30~45 Pcs/min

Product Size Error : ±1mm

Contact Now

Non Woven Disposable Face Mask Manufacturing Machine

Structure introduction: The mechanical part is divided into nine structures: cloth unwinding device, nose line installation device, fuse device, ear belt feeding device, mask folding device, finished product welding device, finished product cutting device and discharging device.

This machine for the fully automatic mask production line (typical models such as N95 mask), equipment whole roll material, multi-layer non-woven cloth roll through composite welding, nasal wire rolling after the melting, two coils of the ear band automatic roll, fixed long cutting after the fuse, and then the body to fold molding, after ultrasonic welding fusion, the final mask rolling cutting molding.

Working conditions

  • Installation site: indoor flat ground;
  • Ambient temperature: 5 ℃ ~ 35 ℃;
  • Relative humidity: < 85% (no condensation)
  • Altitude: < 2000m
  • The working environment shall be free of combustible and corrosive gases, and the air cleanliness shall not be less than 300000;
  • Power supply voltage: 380V ± 10% 50Hz
  • Air source: 0.45mpa-0.65mpa

Parameters:

  • Type:ZPFM95
  • Size:(9M*1.4M*2M)(L*B*H)
  • Cycle:30~45 Pcs/min
  • Failure rate:10min≤8h
  • Power: 380V±10% 50Hz
  • Air supply: 0.6Mpa-0.8Mpa

Features

1. High stability, low failure rate, beautiful appearance without rust.

2. Computer PLC programming control, servo drive, high degree of automation.

3. Photoelectric detection of raw materials to avoid mistakes and reduce waste.

4. The automatic mask making machine is automatic from material feeding to mask collection.
5. High automation in ear-loop welding, edge wrapping, counting, and material discharging.

6. The ultrasonic technique does no harm to the characteristic of the material. Easy and safe operation.
7. Artistic and durable, aluminum alloy board, lean and practicality.
8. Faster, Rotary connection device of Independent innovation design.
9. More stable, upgraded machine, touch screen, Taiwan photoelectric detection, stable performance, and low failure rate.

Daily cleaning and maintenance

  • Clean the table every day
  • All chains and gears of the machine shall be maintained with lubricating oil once a fortnight and dust and debris shall be removed
  • Oil change of main motor reducer once a year
  • When replacing parts for maintenance, turn off the power supply to avoid danger during disassembly. Select the right tools when replacing, and do not use the improper tools to forcibly dismantle.

Monthly inspection and maintenance

  • Oil and lubricate the meshing gears and sprocket chains in the machine drive system, and the lubrication method shall be based on the principle of light coating
  • Oil lubrication on end seal bearing
  • Check the chain and belt tension of transmission parts and tighten them if necessary
  • Check the looseness of screws or nuts of all parts and press them tightly if necessary

Half year maintenance

  • check the wear of the conveyor belt and replace it if necessary.
  • check all kinds of vulnerable parts and replace them in time.
  • check the wear of all transmission parts and replace them if necessary.
  • check and fasten the electrical wiring, and clean the dust on each component with compressed air.

Common faults and Solutions

Item Parts Assy Problem and fault Solutions
1 Fabric unwinding device The discharge shaft makes a buzzing sound and keeps turning

Check whether the displacement sensor steel sheet behind the swing bar is loose, lift the front swing bar, adjust the steel sheet to the sensor sensing position and lock the screw; check whether the cloth is loose and whether the motor is idling,

move the cloth position to the position in the butt welding wheel, and lock
the shaft head.

2 Fabric unwinding device Too much or too little cloth tension The tension of the cloth is equal to the weight of the swing bar. Move the tension spring on the counterweight bar to a distance, so that the tension of the tension spring becomes larger and the gravity of the swing bar becomes smaller, so the tension is smaller. The relative position tension can be adjusted by adjusting the angle of the sensing metal sheet of the
displacement sensor.
3 Fabric
unwinding device
Adjustment of cloth position First adjust the position of the positioning horn with the welding wheel as the center, and then adjust the cloth on the discharge shaft with the positioning horn as the center. The cloth should
be smooth through the positioning horn.
4 Nose Wire Installation device Length adjustment of nose line Loosen the screw on the fixed block of the feeding cylinder to move for a certain distance, then loosen the fastening nut at the end of the feeding cylinder, turn the adjusting nut to adjust. The adjusted distance should be the same as the moving distance of the fixed clamp of the feeding cylinder. The adjusted distance is the extended distance of the nose line;
After the distance adjustment, the fixed screw under the nose line cutter should be loosened to move the nose line cutter so that the center of the cut nose line is in the center of the rotating finger clamp; if the center of the nose line is not in the middle of the rotating finger clamp, the fused nose line will shift on both
sides in turn.
5 Nose Wire Installation device Can't cut off the nose line The main problem with rhinotomy is
1. Is the air pressure sufficient,
2. Whether the cutting edge is damaged
3. Whether the installation position of cutter is correct.
6 Nose Wire Installation device Specification of replacement nose line To change the specification of the nose line, it is necessary to change the fixing clip, feeding clip and finger clip, so that the
width of the clip is the same as that of the nose line.
7 Nose Wire Installation device Rotary clamp position adjustment Adjust the rotation angle of the rotating clamp. First, turn the rotating clamp to the nose line position, and then release the upper sensing disc to align the gap position of the disc with the
sensor and fix it.
8 Fusing device Position adjustment of welding wheel relative to nose line First adjust the position of the adjusting wheel to the center, and then check whether the position of the cloth fusion and the nose line is correct. If the position difference is too much, it is necessary to lift the welding wheel to make the gear on the welding wheel separate from the height of the main driving wheel gear below. Turn the welding wheel to check the welding position; if the position is still a little poor, turn the handwheel
of the regulating wheel to adjust to the exact position.
9 Fusing device Insufficient fusing fastness Adjust the two limit screws to the same height so that the welding wheel is completely pressed on the ultrasonic mold. During the ultrasonic pressing process, it cannot be pressed to the bottom at one time. Try to press slowly to avoid damage to the ultrasonic mold and the fusing wheel;
Check whether the ultrasonic wave is normal.
10 Fusing device Position adjustment of cutter wheel relative to welding wheel 1. The cutting position and welding position are not right before and after. If there is too much difference between the positions, it is necessary to lift the cutter wheel to make the gear on the cutter wheel separate from the height of the main driving gear below. Turn the cutter wheel to check the cutting position; if the position is a little bit worse, turn the handwheel of the adjusting wheel to adjust to the exact position; if the cutting position is not right, loosen the fixed screw under the cutter wheel group, and move the position of the whole cutter wheel group.
2. When the cutter wheel is depressed, observe the pressure sensor gauge connected with the cutter wheel. The number of each row of the pressure gauge represents the pressure of the left and right ends of the cutter wheel. After being depressed,
the pressure at both ends should be adjusted to a similar value.
11 Fusing device Cutter cannot be cut off Check whether the cloth moves to the cutter limit position;
Check whether the pressure of the cutter is enough.
12 Ear loop feeding Length adjustment of ear loop 1. Loosen the screw of the rotating disk, move the protective disk at both ends of the rotating disk, and loosen the screw of the return clamp on the protective disk to move the same
distance.
2. The moving distance of the two protection plates shall be the
same, and the moving distance of the return clip shall be the same as that of the protection plate to avoid collision
13 Ear loop feeding Adjustment of the fastness of the ear belt line 1. For the first adjustment, the height of the ultrasonic mold shall be adjusted to the same as that of the electric board.
2. Loosen the screw
3, and then adjust the screw
4 to adjust the whole ultrasonic part up and down. For the left and right adjustment, loosen the screw
5. After the left and right movement, lock the screw 6. After the ultrasonic mold is adjusted to the correct position, adjust the height of the ear belt spot welding head down, and loosen the nut
7. Turn the adjusting nut
8 of the cylinder to adjust the pressing height of the welding head, loosen the screw
9, move the position and fix the left and right positions of the welding head.
Both ends of ultrasonic mold must be parallel
14 Ear loop feeding Rotation disc angle adjustment The angle adjustment of the rotating disk is mainly the induction disk. First, put the angle position of the rotating disk to the position where the ear belt line is just fused to the reference melting point on the cloth. Loosen the screw and turn the induction disk to adjust so that the gap position is aligned
with the sensor, subject to the light of the sensor.
15 Ear loop feeding Adjustment of opening clamp
and closing clamp
The birdie clamp is mainly used to adjust the connecting shaft of the cylinder, loosen the nut, rotate the connecting shaft up
and down to adjust and fix the nut.
16 Ear loop feeding Bird clip and its fault The birdie clamp is mainly used to adjust the connecting shaft of the cylinder, loosen the nut, rotate the connecting shaft up and down to adjust and fix the nut.
The most frequent failure is the bird clip wear, steel ball wear, spring steel plate fatigue, which leads to bird clip not close or no elasticity;
In this case, the bird clamp and steel ball need to be replaced,
and the spring steel sheet can be installed reversely. If it is seriously damaged, it needs to be replaced.
17 Ear loop feeding Adjustment of scissors position 1. Loosen the screws to move the scissors and fix them.
2. After the scissors are moved, it is necessary to ensure that they do not collide with the rotating plate and the spot welding head of the ear belt, and that the cutting position of the scissors
is the first 10 mm of the scissors mouth. If there are too many, it will lead to problems such as uneven cutting of the ear belt,
incorrect position of the welding mask, continuous cutting, etc.
18 Ear loop feeding Adjustment of spot welding position The front and rear position adjustment can be realized by adjusting the rotating plate under the ear belt spot welding part. The left and right position adjustment needs to loosen the upper fixing screws 8 of the spot welding part and adjust the spot welding mechanism left and right until the proper position is reached, and then tighten the screws;
If it is necessary to adjust the spot welding distance of the ear belt, the ear belt welding head shall be remade according to the
required distance
19 Ear loop feeding Specification replacement and adjustment The position of scissors shall be readjusted when replacing scissors. When replacing the rotating disc, the length of the ear belt needs to be adjusted. When repairing or replacing the cutter wheel and welding wheel, pay attention to whether the cutter position and welding position are misplaced. Always use the same specification when replacing parts to avoid accidents or
damage to the machine.
20 Mask folding device Triangle installation position adjustment 1. First loosen the screw under the triangle plate, and center the left and right positions of the triangle plate with the pulling wheel; then loosen the triangle plate screw, adjust the angle, and make the height of the triangle plate the same as that of the ultrasonic welding and the cutting position of the forming cutter
2. If the position cannot be adjusted correctly, the ultrasonic
welding position and the forming cutter cannot be adjusted
21 Mask folding device Center adjustment of cloth If the cloth is not symmetrical after the triangle plate is folded in half, the adjusting hand wheel can be turned to make the left and right height of the pressing roller unequal to adjust the left and
right offset of the cloth to the symmetrical position.
22 Finished
welding device
Incorrect forming position of mask Turn on the manual operation on the touch screen, press the left
or right movement to adjust according to the actual offset distance until the molding position is correct
23 Finished welding device Weak fusion 1. First, check whether the ultrasonic wave is generated. In the case of normal wave generation, properly adjust the spacing between the two molds
2. Pay attention that the spacing should not be too small to
avoid damaging the mold
24 Finished cutting device Cutter position
and fusion position are misplaced
When the offset is small, turn the adjusting hand wheel properly to align the cutter position with the welding position. When the offset is large, loosen the hand wheel on the edge of the formed cutter wheel, turn the cutter wheel to adjust to a proper position, and then tighten the hand wheel. Finally, adjust the sensing disk
back to the original position.
25 Finished cutting device Function and
adjustment of cutter induction disk
The cutter induction disc controls the material pulling and transportation stop, and controls the origin of the cutter wheel. Coordinate nose line welding and ear band welding. It can be used to adjust the position of nose line by adjusting the sensing
disc
26 Discharging The product can not be discharged in time and is stuck in the cutter wheel position 1. First, check whether the discharge part is blocked by foreign matters, and then check whether the tightness of the discharge belt is appropriate and properly adjusted. Clear the blocked products at the cutter wheel before starting again
2. Do not take it out directly by hand. Be careful not to hurt
your hand with the knife wheel






Product Tags:

KN95 Disposable Breathing Mask Machine

      

0.65mpa KN95 mask making equipment

      
China 0.65mpa 3D KN95 Non Woven Mask Making Machine wholesale

0.65mpa 3D KN95 Non Woven Mask Making Machine Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuxi Sunye Precision Machinery Co.Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)